Dear Mark,

You should try the standard method for absorbing H2S which is cadmium
chloride. My student (some years ago now) Hamid Abdollahi used 3 reaction
bottles in series containing 100 ml 1% CdCl2. This is a basis for a good
standard method for measuring H2S since cadmium sulphide is very insoluble.
Simply filter the cotents of the bottles and dry to constant weight!

Good luck!

Julian







>Does anyone know of a method to trap H2S (hydrogen sulfide) gas.
>Something similar to trapping CO2 in base would be preferable.  We're
>trying to get a handle on what volatile sulfur compounds might be given
>off from 35S-labeled bacteria, and only H2S really came to mind as
>"volatile."
>
>Thanks in advance for any suggestions.
>
>-Mark Fuller
>fuller at envirogen.com
>
>
>-------------------------------------------------------------------
>To reply to the group as well as to the originator, make sure that
>the address biofilms at net.bio.net is included in the "To:" field.
>
>See the BIOFILMS homepage at http://www.im.dtu.dk/biofilms for info
>on how to (un)subscribe and post to the Biofilms newsgroup.


**********************************************************
Professor Julian Wimpenny
School of Pure and Applied Biology
Cardiff University
Cardiff CF1 3TL
Wales, UK
tel: +44 (0) 1222 874974
fax +44 (0) 1222 874305
email: WimpennyJ at cf.ac.uk
**********************************************************




-------------------------------------------------------------------
To reply to the group as well as to the originator, make sure that
the address biofilms at net.bio.net is included in the "To:" field.

See the BIOFILMS homepage at http://www.im.dtu.dk/biofilms for info
on how to (un)subscribe and post to the Biofilms newsgroup.





More information about the Biofilms mailing list

Send comments to us at archive@iubioarchive.bio.net