Dear Axel,

 In response to your reply about the special positions: how exact is 'exactly
on a special position' ? would 0.000, 0.000. 0.501 be considered exactly on
0,0,1/2 ? I presume not. Well, my experience is that there is a drift during
consecutive cycles of Xplor, maybe due to accumulation of rounding errors
(??). A few  cycles ago I put a water molecule on the 2-fold in 0,0.019,0.500
(sg C2), orthogonalized and  refined along. Now it's in 0.000, 0.019, 0.501.
Should I worry and reset it ?  If so, how often should this be checked ? Is it
because  the y coord is undetermined in this case, so Xplor doesn't think
it's really a  special position (unlikely) ?

 Regards,

         Boaz